EASY TO READ
Features 6 digits of bright red 7-segment LED displays that are .55 inches high.
TWO PROGRAMMABLE RELAYS
The standard 10 Amp form C relays allow precise flow rate and batch control.
DUAL POWER OPERATION
Units are designed to operate on 110 VAC or 12-24 VDC.
USER SELECTABLE ANALOG INPUT
The R100 and R/T100 permit standard analog inputs of 0-5V, 0-10V, 1-5V, 4-20mA and 0-20mA.
RATE FUNCTION: R100 AND R/T100
Displays 4.5 digits of user scalable flow rate information.
TOTALIZER FUNCTION: R/T100
Accumulates up to 6 digits of information. The totalizer divider allows total division by 1, 10, 100 or 1000.
Engineering Specification
THE DIGITAL TOTALIZER/RATE METER SHALL:
- Interface directly with Lake Monitors' flow rate transmitters.
- Provide 4.5 digits of rate information and 6 digits of totalized information.
- Have two programmable 10A relays.
- Have user scalable units of measure.
- Have a NEMA 4/IP 65 front panel.
- Have EEPROM memory backup.
- Require a 1/8 DIN panel cutout.
- Be Lake Monitors Number R100 for rate only measurements or R/T100 for rate and totalized measurements.
Mechanical Performance |
Enclosure size: |
1/8 DIN, 3.63" x 1.78" cutout |
Construction: |
high impact ABS |
Temperatures: |
Operating: +41¡ÆF (5¡ÆC) to +130¡ÆF (54¡ÆC)
Storage: -40¡ÆF (-40¡ÆC) to +200¡ÆF (93¡ÆC) |
Humidity: |
0-90% non-condensing |
Weight: |
2 lbs. |
Connections: |
via terminal blocks |
Electronic Performance |
Measuring accuracy: |
¡¾0.25% maximum measuring error. |
Temperature stability: |
<20 ppm over operating range |
Input power: |
110VAC ¡¾15% (8VA) or 12-24VDC (300mA) |
Display: |
6 digit red LED, 0, .55" high digits |
Analog inputs: |
4-20mA, 0-20mA, 0-5VDC, 1-5VDC or 0-10VDC
Selectable from the front panel |
Input impedence: |
current inputs: 100 Ohms
voltage inputs: 115K Ohms |
Resolution: |
14.5 bits |
Input protection: |
over voltage: 50V
over current: 50mA |
Relays: |